Back
back to all categoriesUPS TRIAS RM 31_6/10kVA
The new TRIAS RM UPS system from EFFEKTA® is one of the few 19“ systems with 3-phase input and 1-phase output in 19“ design.
With 6 kVA or 10 kVA output power at power factor 1 allows a setup of a highly available UPS system in 19“ cabinets. By parallel connection up to 4 systems can be combined to achieve n+x redundancy.
The TRIAS RM is thus an ideal solution for servers, banks, industrial/IT equipment, communication systems and other network devices that require comprehensive protection.
Downloads
UPS TRIAS RM 6 / 10 kVA - data sheet
1 file(s) 185.68 KB
UPS TRIAS RM 6 / 10 kVA - Manual
1 file(s) 2.07 MB
Characteristics
- UPS classification VFI-SS-111 according to IEC 62040-3
- Online double converter with sine wave output switchable to ECO mode
- Service-friendly battery exchange
- UPS software for all common operating systems
- Integrated remote emergency stop contact (REPO)
- 24 months warranty
Special feature
- 3-phase input
- Unbeatable price advantage in this power class
- Excellent power factor of 1.0
- Mains feedback THDi <3%
- Automatic battery test adjustable via display
- Parallel redundant n+x operation possible
- Multilingual 2.4“ LC colour touch display
Specifications
Model TRIAS RM | 6 kVA | 10 kVA | |
---|---|---|---|
Power | Nominal power in VA/W | 6000 | 10000 |
Autonomy time | Standard configuration in min at 100%/50% load | 8 / 20 | 10 / 25 |
Longer autonomy times on request | on request | ||
Technology | On-line double converter | VFI-SS-111 according to IEC 62040-3 | |
Phase | Input / Output | 1-phase/1-phase or 3-phase/1phase | |
Input | Nominal voltage configurable | 380/400/415VAC or 220/230/240VAC | |
Input voltage range | 208~478VAC or 120~276VAC | ||
Input frequency range | 40-70Hz (autodetect) | ||
Distortion (THDi) | ≤3% (100% non-linear load) | ||
Output | Output voltage | 220/230/240 VAC | |
Power factor | 1.0 | ||
Voltage regulation | ±1 % | ||
Frequency range | Mains operation: ±1%, ±2%, ±4%, ±5%, ±10% of nominal frequency (optional) Battery operation: 50 Hz / 60 Hz ± 0.2HzBatteriebetrieb: 50 Hz / 60 Hz ± 0,2 Hz | ||
Transfer time | 0 ms | ||
Overload Capability (Line Mode) | ≤110%: for 60 min, ≤125%: for 10 min, ≤150%: for 1 min, ≥150% immediate switchover to the bypass. | ||
Overload Capability (Battery Mode) | ≤110%: for 10 min, ≤125%: for 1 min, ≤150%: for 1 sec, ≥150% immediate switch-off of the UPS. | ||
Voltage form | Sine wave | ||
Crest-Factor | 3:1 | ||
THD | ≤2% @ linear load ≤5% @ non-linear load | ||
Efficiency | Normal Mode | max. 93.5% | |
Battery | Type | maintenance-free sealed lead fleece batteries | |
Expected service life | 5 years (optional 10 years) | ||
DC rated voltage | 192-240VDC adjustable, Standard 240VDC | ||
Max. charging current standard | max. 12A | max. 14A | |
Communication | Interfaces | RS232, RS485, Parallel, REPO, MAINTAIN- AUXSWS port | |
Slots for communication cards | 1 x for Relays- or SNMP-card | ||
Display | LCD-Display and LEDs | ||
Dimensions / weight | Dimensions UPS (HxWxD in mm) | 131 (3HE) x 443 x 675 | |
Weight UPS in kg | 27 | 28 | |
Dimensions (HxWxD mm) | 131 (3HE) x 443 x 720 | ||
Weight battery pack incl. batt. in kg | 80 | ||
Dim. connection box (HxWxD in mm) | 131 (3HE) x 443 x 655 | ||
Weight connection box in kg | 12 | ||
Terminals UPS / connection box | Protection | IP20 | |
Connections Battery | Input | Fixed connection on terminals | |
Environmental conditions | Output | Fixed connection on terminals | |
Protection / Standards | Battery pack | Battery cable with plug from / to UPS | |
Temperature | 0°C – 40°C, 20°C recommended | ||
Humidity | 0-95 % RH (non-condensing) | ||
Safety | EN 62040-1 | ||
EMC | EN 62040-2 class C3 | ||
Standards | CE |
Options for extended communication and highest availability:
- SNMP-/Web or relay card for monitoring in network environment
- Additional battery cabinets to increase the bridging time to several hours
- Special designs available for industrial applications (connections / special housings, etc.)