Back
back to all categoriesDC UPS DIN rail DCH series
Reliability and availability in a small space. The DCH series power supplies with UPS function are the most compact of its kind and impress with extraordinary overload behavior. They are characterized by a variety of applications and their robust IP 20 housing is the perfect solution for all DIN rail applications. By the power boost mode, the DCH offers 300% of the rated power for 4 seconds. Thus, it can be used as a reliable overload protection and is ideally suitable for consumers with high inrush currents, such as electric motors.
Open in the catalogueDownloads
DCH series - data sheet
1 file(s) 676.20 KB
DCH - Manual
1 file(s) 526.91 KB
DCH-series - Declaration of Conformity (DoC)
1 file(s) 3.21 MB
Specifications
DCH | 12 V, 3 A | 12 V, 6 A | 12 V, 10 A | 12 V, 35 A | |
---|---|---|---|---|---|
Input | Rated voltage [VAC] | 115-230-277 | 115-230-277 | 115/230-277 | 115/230-277 |
Voltage range [VAC] | 90 – 305 | 90 – 305 | 90 – 305 | 90-135, 180-305 | |
Output (Normal mode) | Rated voltage [VDC] | 12 | |||
Rated current [A] | 3 | 6 | 10 | 35 | |
Power max. [W] | 36 | 72 | 120 | 420 | |
Efficiency (@ 50% In) | ≥89% | ≥89% | ≥89% | ≥90% | |
Redundant operation or power enhancement | No | No | No | Yes | |
Output | Voltage range [VDC] @ In | 10 – 14.4 [VDC] | |||
Peak current [A] Mains 4 Sec. | 9 | 18 | 30 | 105 | |
Peak current [A] Batt. 4 Sec. | 6 | 12 | 20 | 70 | |
Deep discharge protection | 9,5 ± 0,5 | ||||
Charge current adjustment | Range: 10-100% (max. In) | ||||
Communication | Relay contacts | Messages: normal power or backup operation, discharged or defective battery | |||
Mechanical/ environment | Dimensions HxWxD [mm] | 115x65x135 | 115x65x135 | 115x65x135 | 115x150x135 |
Weight [kg] | 0.60 | 0.60 | 0.60 | 1.55 | |
Operating temperature | -25 bis +70°C | -25 bis +70°C | -25 bis +70°C | -25 bis +70°C | |
Humidity | Humidity (non-condensing) |
DCH | 24 V, 3 A | 24 V, 5 A | 24 V, 10 A | 24 V, 20 A | |
---|---|---|---|---|---|
Input | Rated voltage [VAC] | 115-230-277 | 115-230-277 | 115/230-277 | 115/230-277 |
Voltage range [VAC] | 90 – 305 | 90 – 305 | 90-135/180-305 | 90-135, 180-305 | |
Output (Normal mode) | Rated voltage [VDC] | 24 | 24 | 24 | 24 |
Rated current [A] | 3 | 5 | 10 | 20 | |
Power max. [W] | 72 | 120 | 240 | 480 | |
Efficiency (@ 50% In) | ≥89% | ≥89% | ≥83% | ≥90% | |
Redundant operation or power enhancement | No | Nein | Nein | Ja | |
Output | Voltage range [VDC] @ In | 22 – 28.8 [VDC] | |||
Peak current [A] Mains 4 Sec. | 9 | 15 | 30 | 60 | |
Peak current [A] Batt. 4 Sec. | 6 | 10 | 20 | 40 | |
Deep discharge protection | 19.5 ± 0.5 | ||||
Charge current adjustment | 10-100% (max. In) | ||||
Communication | Relay contacts | Messages: normal power or backup operation, discharged or defective battery | |||
Dimensions HxWxD [mm] | 115x65x135 | 115x65x135 | 115x100x135 | 115x150x135 | |
Mechanical/ environment | Weight [kg] | 0.60 | 0.60 | 0.85 | 1.55 |
Operating temperature | -25 to +70°C | 0.60 | 0.85 | 1.55 | |
Humidity | 95% Humidity (non-condensing) |
DCH | 48 V, 5 A | 48 V, 10 A | 12V,15A/24V,10 A | Multifunction- Display | |
---|---|---|---|---|---|
Input | Rated voltage [VAC] | 115/230-277 | 115/230-277 | 115-230-277 | Main functions: – Monitoring – Configuration – Alarm management – History – Event programming |
Voltage range [VAC] | 90 – 305 | 90 – 305 | 90 – 305 | ||
Output (Normal mode) | Rated voltage [VDC] | 24 | 24 | 12/24 selectable | Consumption: 130mA/ 1.6W typical |
Rated current [A] | 3 | 5 | 15/10 | ||
Power max. [W] | 72 | 120 | 280 | ||
Efficiency (@ 50% In) | ≥89% | ≥89% | ≥91% | ||
Redundant operation or power enhancement | No | No | No |