UPS TRITON PF1_10-40 kVA

With the TRITON PF1 UPS, EFFEKTA® offers a modern, modular online double-converter with 3-phase input and output.
The system is operated with a power module from 10 to max. 40 kVA. In this way, the TRITON achieves a very high-power density. The system is operated with a power module from 10 to max. 40 kVA. In this way, the TRITON achieves a very high-power density.
The TRITON PF1 has a power factor of 1.0 throughout from 10-40 kVA.
Downloads
Characteristics
- UPS classification VFI-SS-111 according to IEC 62040-3
- Online double-converter with sine output THDI ≤ 3%
- Simple service thanks to the modular structure
- Up to 4 systems can be connected in parallel
- Large voltage input window
- High efficiency (up to 95%)
- Switchable to ECO mode (> 98%, line-interactive)
- All models with a power factor of 1.0
- EPO (Emergency Power Off / Remote Power Off)
- Temperature controlled fans
- 3-stage gentle battery charging process
- Extensive communication interfaces
- Management software for all common OS
- 24 months warranty
Specifications
Model TRITON PF1 | 10 kVA | 15 kVA | 20 kVA | 30 kVA | 40 kVA | |
---|---|---|---|---|---|---|
Input (AC) | Nominal power in VA/W | 10000 | 15000 | 20000 | 30000 | 40000 |
Autonomy time @ 100/50% Load (cos. phi 0.8) | As standard in min. | 12 / 30 | 6 / 23 | 12 / 30 | 2 / 13 | 7 / 30 |
higher autonomy times | on request | |||||
Technology | Online double conversion | VFI-SS-111 according to IEC 62040-3 | ||||
Phase | Input / Output | 3-phase / 3-phase | ||||
Input | Nominal voltage configurable | 380/400/415 VAC | ||||
Input voltage range | 208-478 VAC | |||||
Input frequency range | 50/60Hz (autodetect) | |||||
Distortion (THDi) | < 3 % | |||||
Output | Output voltage | 380/400/415 VAC | ||||
Voltage regulation | ±1% | |||||
Power factor | 1,0 | |||||
Frequency range | 50Hz or 60Hz ± 0.2Hz | |||||
Transfer time | 0ms | |||||
Overload Capability (Line Mode) | < 125% for 10 min/ < 150% for 1 min | |||||
Voltage form | Sinewave | |||||
Efficiency | Normal-Mode / ECO-Mode | max. 94.5 / 98% | max. 95.0 / 98% | |||
Battery | Type | maintenance-free sealed lead fleece batteries | 72VDC | |||
Expected service life | 5 years/ optional 10 years | |||||
Max. charging current standard | 14A | 16A | 18A | 20A | ||
Time to recharge | from 2 h., depending on the battery capacity | |||||
Communication | Interfaces | RS232, RS485, Parallel, Intelligent slot, Relay card (optional), SNMP card(optional) | ||||
Communication cards (option) | Relay- or SNMP-card | |||||
Slots for communication cards | 2 | |||||
Display | multilingual LC-display | |||||
Parallel connection | max. 4 units for redundancy or increasing output power | |||||
Dimensions / Weight | Dimensions UPS (HxWxD in mm) | 1600 x 600 x 780 | ||||
UPS weight in kg (with standard battery configuration) | 288 | 288 | 388 | 384 | 573 | |
Weight of battery cabinet in kg | depending on the battery capacity | |||||
Terminals | Protection | IP 20 (optionally higher protection class possible) | ||||
Input | hardwired | |||||
Output | hardwired | |||||
Environmental conditions | Temperature | 0°C – 40°C, 20°C recommended | ||||
Humidity | 0-90 % RH @ 0- 40°C (not condensing) | |||||
Operation noise | < 55 dB | |||||
Safety / Standards | Safety | EN 62040-1 | ||||
EMC | EN 62040-2 class C3 | |||||
Standards | CE |
Options for extended communication and highest availability:
- SNMP/Web or relay card for monitoring in network environment
- Additional battery cabinets to increase the bridging time to several hours
- External manual bypass for scheduled UPS maintenance or UPS replacement without shutdown
- Warranty Extensions