Back
back to all categoriesUPS ADIRA T 0.7-3 kVA
The ADIRA T 0.7-3 kVA with its compact design can be used in even very limited space. The autonomy time can be extended extremely flexibly using external battery packs.
The ADIRA T 0.7-3 kVA has a power factor of 1.0. The UPS shows particular strength in communication. She is u.a. Equipped as standard with an Ethernet port to be connected to the cloud. Furthermore, the UPS can be monitored via WIFI with a mobile APP.
The UPS has extensive setting options, such as password protection, wiring errors, overload alarm
Open in the catalogueDownloads
UPS ADIRA T 0.7-3 kVA - data sheet
1 file(s) 218.26 KB
UPS ADIRA T 0,7-3 kVA - Manual
1 file(s) 3.07 MB
Characteristics
- UPS classification VFI-SS-111 according to IEC 62040-3
- Excellent power factor of 1.0
- Online double-converter with sine output switchable
to ECO mode (line-interactive) - User-friendly dot matrix LCD display
- Very high efficiency of up to 96% in normal operation
- Large input voltage window (160-300VAC)
- LCD display with support for 8 languages
- Low-noise thanks to intelligent fan control
- Larger charger for higher charging currents (XL)
- Operation in ambient temperature up to 45°C
- High overload capacity
- Integrated emergency-stop contact (RPO)
- Incl. RS232/USB and expansion slot
- UPS software for the common operating systems
- 24 months warranty
Specifications
ADIRA T Models | 700, 700 XL | 1000, 1000 XL | 1500, 1500 XL | 2000, 2000 XL | 3000, 3000 XL | |
---|---|---|---|---|---|---|
Power | Nominal Power in VA | 700/700 | 1000/1000 | 1500/1500 | 2000/2000 | 3000/3000 |
Autonomy time 100/50% load | Standard configuration in min. | 10 / 24 | 6 / 15 | 3 / 9 | 6 / 16 | 3 / 10 |
Higher autonomy times | On request | |||||
Technology | Online double conversion | VFI-SS-111 in accordance with IEC 62040-3 | ||||
Phase | Input / Output | 1-phase / 1-phase | ||||
Input | Nominal voltage | 220/230/240VAC | ||||
Input voltage range | 160~300VAC | |||||
Input frequency range | 45~55Hz/54~66Hz (Auto-Sensing) | |||||
Distortion (THDi) | <5% | |||||
Output | Output voltage | 220/230/240VAC | ||||
Voltage regulation | ±1% | |||||
Frequency range | 50/60 ± 0.2 Hz | |||||
Transfer time | None | |||||
Overload Capability | 100%~105%: continuous operation; 105%~125%: > 5 min; 125%~150%: > 30 s; >150%: > 500 ms | |||||
Voltage form | Sinewave | |||||
Efficiency | Normal mode | 93% | 96% | |||
ECO mode | >99% | |||||
Battery | Voltage | 36VDC | 72VDC | |||
Capacity (Ah) | 12V/9Ah | 12V/9Ah | 12V/9Ah | 12V/9Ah | ||
Type | Maintenance free lead-acid battery | |||||
Estimated life time | 5 years, optional 10 years | |||||
Charging current (max) | 1.5 A / 8 A (XL-Version) | |||||
Recharging time | to 90% in 3 hours typical / XL versions depending on battery configuration | |||||
Communication | Interface | RS 232, USB (incl. USB HID function), relay contact, RPO | ||||
Slot for further communication cards | 1 x for optional SNMP or relay card | |||||
Display | LCD display and LED indicators | |||||
Special features | APP control via optional WIFI module RJ45 Ethernet port for direct cloud or local network connection | |||||
Dimensions / Weight | Dimensions UPS (HxWxD in mm) | 220x145x404 | 318x192x428 | |||
Dimensions battery pack (HxWxD in mm) optional and XL-Versions | 220x145x404 | 318x192x428 | ||||
Weight UPS in kg incl. Batt. | 14 | 14 | 14,3 | 26,0 | 26,4 | |
Weight UPS in kg XL-Version without Batteries | 6.4 | 6.4 | 6.7 | 11.0 | 11.4 | |
Weight battery pack in kg with 1 / 2 battery strings | 12/19 | 24/39 | ||||
Protection | IP20 | |||||
Terminals | Input | IEC C14 (10 A) | IEC C14 (10 A) | IEC C14 (16 A) | IEC C20 (16 A) | IEC C20 (16A) XL: terminals |
Output | 4 x IEC C13 (10A) | 4 x IEC C13 (10A) | 4 x IEC C13 (10A) | 8 x IEC C13 (10A) | 8 x IEC C13 (10A) + 1 x IEC C19 (16A) XL: 8 x IEC C13 (10A) + terminals | |
Environmental conditions | Temperature | 0-40° C (@ 80% load up to 45° C) | ||||
Humidity | 20~90% (not condensing) | |||||
Acoustic noise | <40dB (1m / @ typical load) | <45 dB (1 m / bei typischer Last) | ||||
Protection / Standards | Safety | IEC/EN62040-1, IEC/EN60950-1 | ||||
EMC | IEC/EN62040-2 class C2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 | |||||
Certifications | CE |