UPS ADIRA RT 0.7-3 kVA


The ADIRA RT 0.7-3 kVA with its compact design can also be used in very limited space. The autonomy time can be extended extremely flexibly using external battery packs. As a "rack tower" model, it can be set up both vertically and horizontally and is suitable for installation in 19" cabinets. The LCD display can be rotated by 90° for this purpose. The ADIRA RT 0.7-3 kVA has a power factor of 1.0.

The UPS It can be perfectly integrated into your monitoring system thanks to the integrated RS232 and USB interfaces and an optional SNMP card (via the expansion slot). The UPS has extensive setting options, such as password protection, wiring errors, overload alarm.

Open in the catalogue

Downloads

Characteristics

  • UPS classification VFI-SS-111 according to IEC 62040-3
  • Excellent power factor of 1.0
  • Online double-converter with sine output switchable to ECO mode (line-interactive)
  • User-friendly DOT matrix LCD display
  • Very high efficiency of up to 96% in normal operation
  • Large input voltage window (160-300VAC)
  • Programmable load segments/output sockets
  • LCD display with support for 8 languages
  • LCD display can be rotated 90° for device use as a tower or for 19″ installation
  • Low-noise thanks to intelligent fan control
  • Larger charger for higher charging currents (XL)
  • Integrated emergency-stop contact (EPO)
  • Incl. RS232/USB and expansion slot
  • UPS software for the common operating systems
  • 24 months warranty

Specifications

ADIRA RT Models700, 700 XL1000, 1000 XL1500, 1500 XL2000, 2000 XL3000, 3000 XL
PowerNominal Power in VA700/7001000/10001500/15002000/20003000/3000
Autonomy time
100/50% load
Standard configuration in min.10 / 246 / 153 / 96 / 163 / 10
Higher autonomy timesOn request
TechnologyOnline double conversionVFI-SS-111 in accordance with IEC 62040-3
PhaseInput / Output1-phase / 1-phase
InputNominal voltage220/230/240VAC
Input voltage range160~300VAC
Input frequency range45~55Hz/54~66Hz (Auto-Sensing)
Distortion (THDi)<5%
OutputOutput voltage220/230/240VAC
Voltage regulation±1%
Frequency range50/60 ± 0.2 Hz
Transfer timeNone
Overload Capability100%~105%: continuous operation; 105%~125%: > 5 min; 125%~150%: > 30 s; >150%: > 500 ms
Voltage formSinewave
EfficiencyNormal mode93%96%
ECO mode>99%
BatteryVoltage36VDC72VDC
Capacity (Ah)9Ah
TypeMaintenance free lead-acid battery
Estimated life time5 years, optional 10 years
Charging current (max)1.5 A / 8 A (XL-Version)
Recharging timeto 90% in 3 hours typical / XL versions depending on battery configuration
CommunicationInterfaceRS 232, USB (incl. USB HID function), relay contact, RPO
Card Expansion Slot1 x for optional SNMP or relay card
DisplayLCD display and LED indicators
Special featuresAPP control via optional WIFI module
RJ45 Ethernet port for direct cloud or local network connection
Dimensions /
Weight
Dimensions UPS (HxWxD in mm)85.5(2HE) x 438 x 44585.5(2HE) x 438 x 600
Dimensions battery pack (HxWxD in mm) optional and XL-Versions85.5(2HE) x 438 x 44585.5(2HE) x 438 x 600
Weight UPS in kg incl. Batt.
Weight UPS in kg XL-Version without Batteries
15.515.515.825.726.2
8.08.08.210.611.0
Weight battery pack in kg
with 1 / 2 battery strings
15/2325/40
ProtectionIP20
TerminalsInputIEC C14 (10 A)IEC C20 (16 A)IEC C20 (16 A)
Output8 x IEC C13 (10A)8 x IEC C13 (10A)8 x IEC C13 (10A)
1 x IEC C19 (16A)
Environmental
conditions
Temperature0-40° C (@ 80% load up to 45° C)
Humidity20~90% (non-condensing)
Acoustic noise<40dB (1m / @ typical load)<45 dB (1 m / bei typischer Last)
Protection / StandardsSafetyIEC/EN62040-1, IEC/EN60950-1
EMCIEC/EN62040-2 class C2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4,
IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
CertificationsCE


Optional with lithium-iron Phosphate (LiFePo4) batteries

  • Increased operating temperature range
  • Increased number of possible charge/discharge cycles
  • Less weight with the same battery capacity