Back

Hybrid-Inverter SOFAR HYD-series 3-4.6 kW 1-phase


The 1-phase hybrid inverters from the
HYD 3-4.6k-EP series from SOFARSOLAR are solar and battery inverters, energy management and system moni-toring combined in one device.
This combination guarantees the optimal use of solar energy for a maximum self-consumption rate of the PV system.

 

Open in the catalogue

Characteristics

  • Increase self-consumption rates day and night with intelligent battery storage solution
  • Battery charging with solar power
  • Feeding the surplus solar power into the grid

Special feature

  • 2 MPP-trackers
  • Wi-Fi, DC-circuit breaker, current sensor incl.
  • Compatible with various lithium batteries such as Pylontech
  • 5 years manufacturer warranty
  • Different operating modes available
  • Easy monitoring through monitoring App
  • Mode for zero power supply configurable
  • Emergency power function with 100 % power

Specifications

Technical specificationsHYD 3000-EPHYD 3680-EPHYD 4000-EPHYD 4600-EP
Input DC (PV side)Max. PV input power [Wp]4500540060006900
MPPT operating voltage range [V]90 – 580 VDC
Number of MPP trackers13
Max. input current per MPPT [A]18
Max. input short circuit current per MPPT [A]2
Number of strings per MPP-tracker1
Full power MPPT voltage range [V]160-520 VDC180-520 VDC200-520 VDC230-520 VDC
Output / Input AC (Grid side)Nominal AC power [W]3000368040004600
Max. AC power output to utility grid [VA]3300368044004600
Max. AC current output to utility grid [A]15162020,9
Nominal grid voltageL / N / PE, 230 VAC
Power factor (cosφ)1
Output THDi (@Nominal output)< 3 %
Output AC (Emergency Pow-er Supply)Max. apparent power [VA]3000368040004600
Peak output power [VA] / duration3600/60Sek.4400/60Sek.4800/60Sek.5520/60Sek.
Max. output current [A]13,61618,220,9
Nominal voltage, frequencyL / N / PE, 230 VAC
THDv (@Linear load)50/60Hz
Switch time< 3 %
< 10 ms default
Battery Parameters (optional)Battery typeLithium-ion, Lead-acid
Battery voltage range42V-58V
Max. charging / discharging power [W]3750400042505000
Max. charging / discharging current [A]75/7580/8085/85100/100
Charging curveAdaptation to BMS (lithium)
3-Stage adaptive with maintenance (lead batteries)
EfficiencyMPPT-efficiency99,9%
European efficiency of solar inverter97,2%97,3%
imensions (H x W x D) in mm482 x 503 x 183
General dataWeight in kg21,5
Ambient temperature range-25°C ~ 60°C
Inverter-Topologytransformerless
Standby self-consumption<10W
Degree of protectionIP65 (not intended for outdoor use)
Noise<25(dB)
LC-Displayyes
CommunicationCAN 2.0 / RS485 / WI-FI / GPRS/Ethernet (Option)
connections(AC)Terminal connections
(DC)MC4
Protection Over/under voltage, ground fault monitoring, reverse polarity protection, DC isolation fault
normsGridDIN VDE V 0126-1-1, VDE-AR-N 4105, DIN VDE V 0124-100
EMVEN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11,EN 61000-3-12
SafetyIEC 62109-1, IEC 62109-2, IEC62040-1
back to all categories