UPS MINERVA 31_10/15/20 kVA

The MINERVA 31 is currently the most compact double conversion UPS system with 3-phase input and 1-phase output for use in the smallest space. It can be extended extremely fl exibly in terms of autonomy time by means of external battery packs. In addition, the input can also be confi gured as 1-phase in addition to 3-phase.
The current consumption is almost ideally sinusoidal. Furthermore, the MINERVA 31 offers an output power factor of 1.0.
With an effi ciency of up to 94.5% in normal operation, it is one of the most effective and economical UPS systems on the market and thus ideally suited for saving money.
Descargas
Características
- UPS classification VFI-SS-111 according to IEC 62040-3
- Online double converter with sine wave output switchable to high efficiency mode
- Battery remaining time display on LCD
- Extraordinarily compact design
- Service-friendly battery replacement
- UPS software for all common OS
- Incl. RS232/USB and expansion slot
- Integrated emergency stop contact (REPO)
- 24 months warranty
Característica especial
- Unbeatable price advantage in this power class
- Outstanding power factor of 1.0
- Outstanding efficiency of up to 94.5% in normal operation
- Line feedback THDi <2.5%
- Automatic battery test adjustable via display
- Low-noise due to intelligent fan control
- Dry-In/Dry-Out interface as standard
- Parallel redundant operation possible
- Multilingual 7“ LC colour touch display
Especificaciones
Model MINERVA 31 | 10 kVA | 15 kVA | 20 kVA | |
---|---|---|---|---|
Input (AC) | Nominal power in VA/W | 10000 / 10000 | 15000 / 15000 | 20000 / 20000 |
Autonomy time @ 100 / 50% Load | As standard in min. | 2 / 10 | 6 / 16 | 2 / 10 |
higher autonomy times on request | On request | |||
Technology | Online double conversion | VFI-SS-111 according to IEC 62040-3 | ||
Phase | Input | 380/400/415 VAC, (3Ph+N+PE) or 220/230/240 VAC, (L+N+PE) | ||
Output | 220/230/240 VAC, (L+N+PE) | |||
Input | Nominal voltage configurable | 380/400/415VAC or 220/230/240VAC | ||
Input voltage range | 208~478VAC or 120~276VAC | |||
Input frequency range | 40-70Hz (autodetect) | |||
Output | Output voltage | 220/230/240 VAC | ||
Voltage regulation | ±1 % | |||
Frequency range | 50 Hz / 60 Hz ± 1 Hz | |||
Transfer time | none | |||
Overload Capability (Line Mode) | < 125% for 10 min., < 150% for 30 Sek. | |||
Voltage form | Sine wave | |||
Efficiency | Normal-Mode | Max. 94.5% | 92 % | 92 % |
ECO- Mode | Max. 98% | 96 % | 96,5 % | |
Battery | Type | maintenance-free sealed lead fleece batteries | 76,8 V / 6 AH | 76,8 V / 9 AH |
Expected service life | 5 years / optional 10 years | |||
Nominal DC-voltage | 192-240VDC configurable | |||
Max. charging current standard | max. 20 A | |||
Time to recharge | from 2 h. to 90%, depending on the battery capacity | |||
Communication | Interfaces | RS232, USB, Relay, EPO, Parallelport | ||
Slots for communication cards | Optional Relay card or SNMP- card | |||
Display | multilingual LC-display and LED | |||
Dimensions / Weight | Dimensions UPS (HxWxD in mm) | 868 x 250 x 900 | ||
Dimensions battery cabinet (HxWxD in mm) optional | 868 x 250 x 828 | |||
UPS weight in kg (with standard battery configuration) | 118 1×20 pcs. | 173 2×20 pcs. | 174 2×20 pcs. | |
Weight of battery cabinet in kg | depending on the battery configuration | |||
Protection | IP20 | |||
Input | hardwired | |||
Terminals | Output | hardwired | ||
Temperature | 0°C – 40°C, 20°C recommended | |||
Environmental conditions | Humidity | 0-90 % RH @ 0- 40°C (not condensing) | ||
Safety | EN 62040-1 | |||
Safety / Standards | EMC | EN 62040-2 Class C3 | ||
Standards | CE |
Options for extended communication and highest availability:
- SNMP/web or relay card for monitoring in network environments
- Additional battery modules to increase the bridging time to several hours
- External manual bypass for scheduled UPS maintenance or UPS replacement without shutdown
- Special designs available for industrial applications (connections / special enclosures, etc.)