UPS ADIRA RT 0,7-3 kVA

UPS ADIRA RT 0,7-3 kVA: Compact UPS for industrial applications

The ADIRA RT 0,7-3 kVA with its compact design can also be used in very limited spaces. Its autonomy time can be extended extremely flexibly using external battery packs. As a "rack tower" model, it can be set up both vertically and horizontally and is suitable for installation in 19" cabinets. The LCD display can be rotated by 90° for this purpose. The ADIRA RT 0,7-3 kVA has a power factor of 1,0. The UPS can be perfectly integrated into your monitoring system thanks to the integrated RS232 and USB interfaces and an optional SNMP card (via the expansion slot). The UPS has extensive setting options, such as password protection, wiring errors, overload alarm.
data sheet (PDF, 180.97 KB)
Suitable accessories

Features

  • 36 months warranty
  • UPS classification VFI-SS-111 according to IEC 62040-3
  • User-friendly DOT-Matrix LCD display
  • input voltage window (160-300 VAC)
  • Low noise thanks to intelligent fan control
  • Larger charger for higher charging currents (XL)
  • Excellent power factor of 1,0
  • Incl. RS232/USB and expansion slot
  • Integrated emergency stop contact (EPO)
  • LCD display can be rotated 90° for use as a tower or for 19“ installation
  • LCD display with support for 8 languages
  • Online double converter with sine output switchable to ECO mode (line-interactive)
  • Programmable load segments/output sockets
  • Very high efficiency of up to 96% in normal operation
  • UPS software for common operating systems

Technical details


ADIRA T models700, 700 XL1000, 1000 XL1500, 1500 XL2000, 2000 XL3000, 3000 XL
OfferingRated power in VA/W700/7001000/10001500/15002000/20003000/3000
bridging time
100/50% load
Standard equipment in min.10 / 246 / 153 / 96 / 163 / 10
Longer autonomy times on request
Technologyonline double converterVFI-SS-111 according to IEC 62040-3
phasesinput / output1-phase / 1-phase
Inputnominal voltage220/230/240VAC
Input voltage range160~300VAC
input frequency range45~55Hz/54~66Hz (automatic detection)
grid perturbations THDi<5%
Outputoutput voltage220/230/240VAC
Voltage regulation± 1%
frequency range50/60 ± 0.2 Hz
switching timeno
Overload Normal Operation100%~105%: continuous operation; 105%~125%: > 5 min; 125%~150%: > 30 s; >150%: > 500 ms
voltage formSine
Efficiencynormal operation93 %96 %
ECO mode>99%
Batterytension36VDC72VDC
Capacity (Ah)9Ah
TypeSealed maintenance-free lead-acid batteries
service life expectancy5 years (optional 10 years)
Maximum charging current1,5 A / 8 A (XL version)
time to rechargeto 90% in about 3 hours typically / XL versions depending on battery configuration
Communication interfaceRS 232, USB (including USB HID function), relay contact, RPO
Expansion slot1 x for optional SNMP or relay card
DisplayLCD display and LED indicators
Dimensions / weightUPS dimensions (HxWxD in mm) 85,5(2HE) x 438 x 44585,5(2HE) x 438 x 600
Dimensions battery pack (HxWxD in mm) optional and XL versions85,5(2HE) x 438 x 44585,5(2HE) x 438 x 600
Weight UPS in kg including batteries15,515,515,825,726,2
Weight UPS in kg XL version without batteries8,08,08,210,611,0
Weight of battery pack in kg with 1 / 2 battery strings15/2325/40
Protection classIP20K
ConnectionsInputIEC C14 (10 A)IEC C20 (16 A)IEC C20 (16 A)
Output4 x IEC C13 (10A)8 x IEC C13 (10A)8 x IEC C13 (10A)
1 x IEC C19 (16A)
ambient
conditions
Temperature0-40° C (at 80% load up to 45° C)
humidity20~90% (non-condensing)
Operating noise<45 dB (1 m / at typical load)<50 dB (1 m / at typical load)
protection / standardsSafetyIEC/EN62040-1, IEC/EN60950-1
EMCIEC/EN62040-2 Klasse C2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4,
IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
approvalsCE
Matching this

UPS management software Powershut-Plus

PowerShut Plus UPS software provides multi-server shutdown, graphical UPS data display and event notifications via email, SMS or fax.

19" rackmount rails (ks1041-0017)

19" rackmount rails (ks1041-0017)
EFFEKTA 19" rackmount rails (KS1041-0017) provide secure mounting for 2U UPS devices. Adjustable depth 498-800 mm, including mounting material.

relay plug-in card (Z0C/AS400)

Enables the galvanically isolated exchange of signals between the UPS and the control system. Configuration via serial interface, no PC software required.

External Bypass 19" (ZBBKSBBP1RM16V10)

Bypass switch 16 A 19“ for UPS systems up to 3000 VA for rack mounting.

Schuko power strip (ZSO02103XX-000)

Power strip with 3 protective contact sockets and 10 A cold appliance plug (IEC 320 C14).

Power Distribution Unit PDU 16 A

Reliable power distribution for data centers and UPS systems, essential for the safe operation of connected devices.

Power Distribution Unit PDU 10 A

Reliable power distribution for data centers and UPS systems, essential for the safe operation of connected devices.

UPS management SNMP CS 141

CS 141 adapters are available as a stand-alone version and as a slot card.