UPS 1-3 KW RT Lithium: Lithium-based uninterruptible power supply for industrial applications
The RT Lithium with its compact design can also be used in very confined spaces. It provides long bridging times thanks to the lithium battery and offers an extraordinarily high cycle stability with over 2000 charge/discharge cycles. The current consumption is almost ideally sinusoidal. The RT Lithium also offers a power factor of 1,0. With the adjustable current distribution, non-critical consumers can be switched off in battery operation in order to extend the autonomy time.
data sheet (PDF, 185.55 KB)
Features
- 30% lower weight of the entire system
- This results in a much longer battery life than conventional lead batteries
- Low service costs due to less frequent battery replacement
- High number of cycles of the lithium battery (over 2000)
- Can be used in higher temperature windows
- Incl. RS232/USB and expansion slot
- Integrated emergency stop switch (EPO)
- UPS software for common OS
Features
- 36 months warranty
- Can be used as a tower or 19" version
- Large voltage input window
- UPS classification VFI-SS-111 according to IEC 62040-3
- User-friendly rotating LCD display
- Excellent power factor of 1,0
- Compact design of only 2 HE
- Online double converter with sine output switchable to ECO mode (line-interactive)
Technical details
| Model RT Lithium | 1 kVA | 2 kVA | 3 kVA | |
|---|---|---|---|---|
| Offering | Rated power in VA/W | 1000/1000 | 2000/2000 | 3000/3000 |
| bridging time | 100% load (PF 0,7) | 9 | 9 | 9 |
| Technology | online double converter | VFI-SS-111 according to IEC 62040-3 | ||
| phases | input / output | 1-phase / 1-phase | ||
| Input | Nominal voltage configurable | 230, 240 VAC | ||
| Input voltage range | 160-300 VAC, ±5 % | |||
| input frequency range | 40-70 Hz (automatic detection) | |||
| Output | output voltage | 230, 240 VAC | ||
| Voltage regulation | ±1 % | |||
| frequency range | 46~54 Hz (at 50 Hz) or 56~64 Hz (at 60 Hz) | |||
| switching time | no | |||
| Overload Normal Operation | 105~125 % for 1 minute, 125~130 % for 30 sec., >130 % for 0,2 seconds, then switch to bypass | |||
| overload battery operation | 105~125% for 1 minute, 125~130% for 10 seconds, >130% for 0,2 seconds then shutdown of the UPS output |
|||
| voltage form | Sine | |||
| Efficiency | normal operation | 90% | 92% | 92% |
| ECO mode | 95% | 96% | 96,5% | |
| Battery | type (lithium) | 25,6V / 9AH | 76,8V / 6AH | 76,8V / 9AH |
| service life expectancy | Approx. 10 years / over 2000 charge / discharge cycles | |||
| Maximum charging current | 2 A | |||
| Communication | interface | RS 232 / USB | ||
| Expansion slot | 1 x for optional SNMP or relay card | |||
| Display | LCD display and LED indicators | |||
| Dimensions / weight | UPS dimensions (HxWxD in mm) as a 19" installation variant | 86,5x440x325 | 86,5x440x500 | 86,5x440x640 |
| Weight UPS in kg including batteries | 9,6 | 16,1 | 20,97 | |
| Protection class | IP20K | |||
| Input | IEC (10 A) | IEC (16 A) | IEC (16 A) | |
| Connections | Output | 8 x IEC C13 (10A) | 8 x IEC C13 (10A) | 8 x IEC C13 (10A) 1 x IEC C19 (16 A) |
| Temperature | -25 ~ 55 ° C | |||
| Environmental conditions | humidity | 0~95% (non-condensing) | ||
| Operating noise | <55 dB (1 m) | |||
| Safety | IEC/EN62040-1, IEC/EN60950-1 | |||
| protection / standards | EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
||
| approvals | CE | |||
Matching this