UPS 1-3KW RT Lithium

UPS 1-3KW RT Lithium

The RT Lithium with its compact design can be used in very limited space. Thanks to the lithium battery, it provides long autonomy times and, with over 2000 charge/discharge cycles, offers an extraordinarily high cycle stability. The power consumption is almost ideally sinusoidal. Furthermore, the RT Lithium offers a power factor of 1.0. With the adjustable current distribution, non-critical consumers can be switched off in battery operation in order to extend the autonomy time.
data sheet (PDF, 196.60 KB)

Features

  • 30% lower weight of the entire system
  • Can be used in a higher temperature range
  • High number of cycles of the lithium battery (over 2000)
  • Incl. RS232/USB and expansion slot
  • Integrated emergency stop switch (EPO)
  • Low service costs due to less frequent battery replacement
  • This means far longer battery life than conventional lead-acid batteries
  • UPS software for the common OS

Features

  • 24 months' warranty
  • Can be used as a tower or 19“ version
  • Compact design of only 2 U
  • Excellent power factor of 1.0
  • Large voltage input range
  • Online double converter with sine output switchable to ECO mode (line-interactive)
  • UPS classification VFI-SS-111 according to IEC 62040-3
  • User-friendly rotatable LCD display

Technical details


Model RT Lithium1 kVA2 kVA3 kVA
PowerNominal power in VA/W1000/10002000/20003000/3000
Autonomy time 100% load (PF 0,7)999
TechnologyOnline double conversionVFI-SS-111 according to IEC 62040-3
PhaseInput / Output1-phase / 1-phase
InputNominal voltage configurable230, 240 VAC
Input voltage range160-300 VAC, ±5 %
input frequency range40-70 Hz (auto-detect)
outputOutput voltage230, 240 VAC
Voltage regulation±1 %
Output frequency range46~54Hz (@ 50Hz) or 56~64Hz (@ 60Hz)
Switching timenone
Overload Capability
(Line mode)
105~125% for 1 minute, 125~130% for 30 seconds, >130% for 0.2 seconds after each switching to bypass
Overload Capability
(Battery mode)
105~125% for 1 minute, 125~130% for 10 seconds, >130% for 0.2 seconds, then the UPS output is switched off
Voltage formSine wave
Efficiencynormal mode90%92%92%
ECO mode95%96%96,5%
BatteryType (Lithium)25.6V/9AH76.8V/6AH76.8V/9AH
life timeApprox. 10 years / over 2000 charge/discharge cycles
Charging current (max)2 A
CommunicationInterfacesRS 232 / USB
Expansion slot1 x for optional SNMP or relay card
DisplayLCD display and LEDs
Dimensions / WeightDimensions UPS (HxWxD in mm) as 19“ version86.5x440x32586.5x440x50086.5x440x640
Weight UPS in kg including batteries9.616.120.97
ProtectionIP20
InputIEC (10 A)IEC (16 A)IEC (16 A)
terminalsoutput8 x IEC C13 (10A)8 x IEC C13 (10A)8 x IEC C13 (10A)
1 x IEC C19 (16 A)
Temperature-25 ~ 55 ° C
Environmental
conditions
Humidity0~95% (non-condensing)
Acoustic noise<55 dB (1 m)
SafetyIEC/EN62040-1, IEC/EN60950-1
Safety / StandardsEMCIEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4,
IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
StandardsCE