UPS 1-3KW RT Lithium
The RT Lithium with its compact design can be used in very limited space. Thanks to the lithium battery, it provides long autonomy times and, with over 2000 charge/discharge cycles, offers an extraordinarily high cycle stability. The power consumption is almost ideally sinusoidal. Furthermore, the RT Lithium offers a power factor of 1.0. With the adjustable current distribution, non-critical consumers can be switched off in battery operation in order to extend the autonomy time.
data sheet (PDF, 196.60 KB)
Additional Information
Downloads
Features
- 30% lower weight of the entire system
- Can be used in a higher temperature range
- High number of cycles of the lithium battery (over 2000)
- Incl. RS232/USB and expansion slot
- Integrated emergency stop switch (EPO)
- Low service costs due to less frequent battery replacement
- This means far longer battery life than conventional lead-acid batteries
- UPS software for the common OS
Features
- 24 months' warranty
- Can be used as a tower or 19“ version
- Compact design of only 2 U
- Excellent power factor of 1.0
- Large voltage input range
- Online double converter with sine output switchable to ECO mode (line-interactive)
- UPS classification VFI-SS-111 according to IEC 62040-3
- User-friendly rotatable LCD display
Technical details
Model RT Lithium | 1 kVA | 2 kVA | 3 kVA | |
---|---|---|---|---|
Power | Nominal power in VA/W | 1000/1000 | 2000/2000 | 3000/3000 |
Autonomy time | 100% load (PF 0,7) | 9 | 9 | 9 |
Technology | Online double conversion | VFI-SS-111 according to IEC 62040-3 | ||
Phase | Input / Output | 1-phase / 1-phase | ||
Input | Nominal voltage configurable | 230, 240 VAC | ||
Input voltage range | 160-300 VAC, ±5 % | |||
input frequency range | 40-70 Hz (auto-detect) | |||
output | Output voltage | 230, 240 VAC | ||
Voltage regulation | ±1 % | |||
Output frequency range | 46~54Hz (@ 50Hz) or 56~64Hz (@ 60Hz) | |||
Switching time | none | |||
Overload Capability (Line mode) | 105~125% for 1 minute, 125~130% for 30 seconds, >130% for 0.2 seconds after each switching to bypass | |||
Overload Capability (Battery mode) | 105~125% for 1 minute, 125~130% for 10 seconds, >130% for 0.2 seconds, then the UPS output is switched off | |||
Voltage form | Sine wave | |||
Efficiency | normal mode | 90% | 92% | 92% |
ECO mode | 95% | 96% | 96,5% | |
Battery | Type (Lithium) | 25.6V/9AH | 76.8V/6AH | 76.8V/9AH |
life time | Approx. 10 years / over 2000 charge/discharge cycles | |||
Charging current (max) | 2 A | |||
Communication | Interfaces | RS 232 / USB | ||
Expansion slot | 1 x for optional SNMP or relay card | |||
Display | LCD display and LEDs | |||
Dimensions / Weight | Dimensions UPS (HxWxD in mm) as 19“ version | 86.5x440x325 | 86.5x440x500 | 86.5x440x640 |
Weight UPS in kg including batteries | 9.6 | 16.1 | 20.97 | |
Protection | IP20 | |||
Input | IEC (10 A) | IEC (16 A) | IEC (16 A) | |
terminals | output | 8 x IEC C13 (10A) | 8 x IEC C13 (10A) | 8 x IEC C13 (10A) 1 x IEC C19 (16 A) |
Temperature | -25 ~ 55 ° C | |||
Environmental conditions | Humidity | 0~95% (non-condensing) | ||
Acoustic noise | <55 dB (1 m) | |||
Safety | IEC/EN62040-1, IEC/EN60950-1 | |||
Safety / Standards | EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
||
Standards | CE |