Air-cooled all-in-one battery system OPTIM US A100-HY
The OPTIM US A100-HY is an air-cooled, high-voltage battery storage system based on lithium iron phosphate batteries. This system is particularly suitable for industrial and commercial applications, such as peak shaving and valley filling, increasing power capacity, storage systems for photovoltaic installations, and emergency power supplies. Designed for outdoor use, the battery storage system connects the power grid to the storage battery via a hybrid inverter, enabling bidirectional energy transfer between the DC battery of the storage system and the AC grid.
data sheet (PDF, 612.16 KB)
Additional Information
Downloads
Product Features
- Integrated hybrid inverter.
- Maximum safety.
- Flexible configuration.
- Easy setup and maintenance.
- Load peak capping
Technical details
| General data | M1C 100kW/104kWh |
|---|---|
| Dimensions (W*D*H mm, without inverter) | 1500 * 1125 * 2195 |
| Weight (tons) | 1,9 (including battery) |
| Operating temperature range (°C) | -20-50* |
| IP protection class | IP55K |
| Sea level | ≤2000 |
| humidity | 0 ~ 95% |
| Firefighting | Aerosol |
| Cooling system | air cooling |
| Cooling system power consumption (kW, cooling/heating) | 2/1 |
| Auxiliary power consumption (kW, continuous/peak, incl. HVAC) | 1,5/3 |
| Maximum number of parallel | 5 |
| Corrosion Protection | C3 (C5 optional) |
| Certification | UN38.3/UN3481/IEC62619/IEC62040-1/CE/UKCA(EMC/RED)/VDE2510-50/UL1973/UL9540A/UL9540 G99/VDE-AR-N 4105/EN 50549-1/EN 50549-10/EIFS 2018.2/IEC 62116/IEC 61727/ IEC 60068/IEC 61683/EN 50530 |
| Battery data | M1C 100kW/104kWh |
|---|---|
| battery type | Li-ion (LFP) |
| Nominal capacity (kWh) | 104 |
| Max. / continuous C-rate | 1/0,5 |
| depth of discharge | 98% (single strand) |
| Cycle life | > 7000 |
| DC voltage range (VDC) | 594-792 (single strand) |
| Max. / Continuous operating current (A) | 148/74 |
| Overall efficiency at 0,5 C-rate | 95 % |
| Hybrid data in network operation | M1C 100kW/104kWh |
|---|---|
| AC rated power (kW) | 50/100 |
| AC nominal output voltage (Vac) | 400 |
| AC nominal output frequency (Hz) | 50/60 |
| Maximum AC current (A) | 76 (Linear Load) |
| Overload capacity | 110 % |
| AC power factor | >0,99 (0,8 leading ~ 0,8 lagging) |
| CEC efficiency | 97,4% (max. 97,8%) |
| Insulation type | no isolation |
| Response time (mains operation to island operation) | <10ms |
| operation mode | M1C 100kW/104kWh |
|---|---|
| Communication type | Modbus TCP/IP, Modbus RTU |
| Operational logic | Peak load shaving/load shifting/self-consumption/backup |
| *Degradation occurs at temperatures below 10°C or above 40°C. | |