Line-Interactive MTD-RT series

Line-Interactive MTD-RT series: Reliable protection for UPS systems

The MTD RT and MTD XL RT is EFFEKTA®'s high-end version of the line-interactive MTD series. The autonomy time of the XL models can be extended by additional external battery packs in a uniform design. Its rack tower housing and the rotating LCD display enable it to be used as a tower device as well as installed in 19" cabinets.
data sheet (PDF, 1.10 MB)
Suitable accessories

Features

  • "Racktower" stand-alone unit or 19" built-in unit
  • 36 months warranty
  • Automatic frequency detection
  • slot for optional adapters
  • Excellent power factor of 0,9
  • Backlit LCD display
  • High efficiency (>97%)
  • Hot-Swap: Batteries can be replaced during operation
  • line-interactive technology
  • management software
  • Programmable current outputs
  • RS-232 and USB interface as standard
  • sine wave output
  • UPS classification VI-SS-311 according to IEC 62040-3
  • Wide input voltage range
  • XL models can be expanded with external battery packs

Technical details


MTD1000 RT1500 RT2000 RT3000 RT
PerformanceRated power in VA1000150020003000
Rated power in W900135018002700
bridging time
100% / 50% load
(cos. phi 0,7)
Standard equipment in min.7 / 155 / 117 / 155 / 11
longer autonomy times on request (XL variant)
TechnologyLine-InteractiveVI-SS-311 according to IEC 62040-3
phasesinput / output1-phase / 1-phase
InputNominal voltage configurable220/230/240 VAC
Input voltage range161-276 VAC
input frequency range50/60 Hz (automatic detection)
Outputoutput voltage220/230/240 VAC
Voltage regulation± 5%
frequency range50 Hz or 60 Hz ± 1 Hz
switching time2-6 ms typical / 10 ms max.
Overload Normal Operation< 110% for 3 minutes
overload battery operation< 110% for 30 seconds
voltage formSine
Efficiencynormal operationmax 97%
BatteryTypemaintenance-free lead-acid batteries
service life expectancy5 years, optionally 10 years
Maximum charging current1,5A standard / 4,5A XL version / from. 2 battery packs 7A
Hot swappableja
time to rechargeapprox. 6 hours at 90% capacity
Communication interfaceRS232, USB, EPO
slot for additional communication cardOptional relay or SNMP card
DisplayLC display
Dimensions /
Weight
UPS dimensions (HxWxD in mm)86,5 (2U) x 438 (19”) x 43086,5 (2U) x 438 (19”) x 600
Dimensions battery extension (HxWxD in mm) optional86,5 (2U) x 438 (19”) x 43086,5 (2U) x 438 (19”) x 600
Weight UPS in kg (Standard / XL)16 / 1229,5 / 18,6
weight of the battery bankdepending on the equipment
Protection classIP 20 (higher protection classes available optionally)
ConnectionsInputIEC (10 A)IEC (16 A)
Output programmable in segments8 x IEC C13 (10 A)8 x IEC C13 (10 A)
1 x IEC C19 (16 A)
Environmental conditionsTemperature0°C – 40°C, 20°C recommended
humidity0-90 % RH @ 0- 40°C (non-condensing)
Operating noise<52 dB
protection / standardsSafetyEN 62040-1
EMCEN 62040-2 Class C2
approvalsCE
Matching this

UPS management software Powershut-Plus

PowerShut Plus UPS software provides multi-server shutdown, graphical UPS data display and event notifications via email, SMS or fax.

19" rackmount rails (ks1041-0017)

19" rackmount rails (ks1041-0017)
EFFEKTA 19" rackmount rails (KS1041-0017) provide secure mounting for 2U UPS devices. Adjustable depth 498-800 mm, including mounting material.

External Bypass 19" (ZBBKSBBP1RM16V10)

Bypass switch 16 A 19“ for UPS systems up to 3000 VA for rack mounting.

Schuko power strip (ZSO02103XX-000)

Power strip with 3 protective contact sockets and 10 A cold appliance plug (IEC 320 C14).

Power Distribution Unit PDU 16 A

Reliable power distribution for data centers and UPS systems, essential for the safe operation of connected devices.

Power Distribution Unit PDU 10 A

Reliable power distribution for data centers and UPS systems, essential for the safe operation of connected devices.